15+ we switched to using semver. That seemed to be the problem, I got my me system working again, I just had to remove and change some cables, thx. A Network requires power, which can be provided by various blocks, and may require ME. The ME Network is a multi-block structure added by the Applied Energistics 2 mod. Thats why you need the cells, they increase your Maximum rf storage, and therefore your maximum possible. 10 now I'm trying to replicate my old setup without luck. ME Controller • ME Covered Cable. a 3x10x10 would work, but a 1x10x10 would not). MeefMagnet goes through how to increase the size of your ME Controller and how to reorganize it for maximum usable channels. The maximum size of the connected block ix 7x7x7 (343 blocks). AE2 - Device Missing Channel - Have to break ME controller and replace to fix. Maximum size of the ME Controller multiblock is now configurable. Use multiple cells/drives. 2. An updated guide on large ME controllers and P2P networking. Key things to remember about channels: Each side of a controller block can support 32 channels. Applied Energistics 2: ID Name : appliedenergistics2:item. . Already on version 1. In this build, I created a structure that would effectively allow 22,606 machines to be attached to a single Network. Applied Energistics is a Minecraft Mod which contains an advanced storage system called ME that lets you store items compactly and in the way you want, as well as do intricate automation. My understanding of the rules of Controllers that there can only be one set of controllers per network, the controller multiblock can be 7*7*7 at the largest, and all blocks must have at least 2 adjacent sides sides exposed. Without the limit on channels, the ME Controller offers no bonuses over the power acceptor (besides looking cooler). The first step to getting started in AE2 is to acquire Quartz. 1 AE2 Channel Surfing for Newbies (A Reference Guide for the Rest Of Us!) 1. Ae2 and drawers are compatible. One side of an ME controller can provide a bus for 32 systems. The P2P Tunnel cannot extract items from machines, a pipe transport system or ME Export Bus is used or items can be. ago. I have chunk loaders at my Jurassic park and my main base. Manages a single auto crafting task from start to finsh, built of various crafting units. About 1/4 machine automation, 1/4 autostocking, and the rest crafting interfaces. Medium Spatial Cell which can store 16x16x16 regions of space. 7. Better to just learn how to manage channels with p2p, multiple controllers, and using anchors to separate bundles of dense cable. That means it could provide a bus for 32 ME drives with 10 16M storage cells each. ago. That means it can transfer 16krf/t. All controllers on a network must be connected pretty self explanatory. You shouldn't configure anything else on the storage bus. This article is about ME Controller from Applied Energistics 2 . The center of your ae2 system is typically a structure of me controllers, where each face can give you 32 channels. Type : Item Stackable : Yes (64) Solid : Yes Transparent : No Affected by Gravity : No Emits Light : No Flammable : No Required Tool : The Cable Anchor is an item added by the Applied Energistics 2 mod. The ME crafting terminal a great block to add to your ME network. It is used to interact with a group of drawers. I'm finding that when my ME network gets to a larger size (to the level of hundreds of connected interfaces/buses), it keeps freezing up. Each of these towers currently uses 28 channels - 22 interfaces and 6 Crafting CPUs. Browse all gaming. For any more channels you need a controller but if your just using a couple drives ad hoc should work perfectly for nowApplied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). cfg" and open -> Find the following ->. What I don't like about AE2's CPU is you need 3 parts: the CPU, an ME interface, and a molecular. That's 32x32 channels (1,024) going through a single dense cable line. dman11235 is on the right track, but to expand a bit. This build is actually one of the oldest things in this save, made at around 80 hours played. 今回はME Controllerをクラフトするべく様々な工業Modの要素を進めていきます。. The ME Terminal is an item added by the Applied Energistics 2 mod. I suggest using a Bulk Storage solution, and then for general storage. The controller is 32 channels per face, so 1 controller can output 192 channels total if you use all 6 faces. The ME Controller has a maximum length of 7 blocks total B. And when all channels are used to connecting P2P tunnels (and P2p tunnels can handle 32 channels each), I can use 32*32 channels out of single side of ME controller theoretically. You can support me and the channel! Read more here: have done videos. They are usually very limited in scope and rarely directly accessed by the player (mostly for automation). . r/feedthebeast. (2) One chest. Der Mod der das möglich macht, nennt sich applied Energistics 2. • 8 yr. To fix this people build it in a box shape with only the corners of the box, or if you're like me, a line. Or you can connect separate energy acceptors to the sub networks. I just logged on and now its doing nothing at all :S really strange, i can access the system/items but its not processing anything and there are still ores and dusts in the system, also there. You configure the connections by using the ME Bus Memory Card; First Shift+Right Click the input to save it on your memory card, then simply right click the diffrent outputs to store the input onto the. When taken by itself, the ME Controller does nothing. 1) Wire the 5 p2p ends from one side, the bottom 2, and the bottom 1 on the back side. ago. It's like the regular item storage turning matter into data, but these can turn a cubic region of the world into data. I usually have 2 dense cable coming out from the controller, that's face for connecting p2ps. Depends on what you're running though. In total: 22816 channels through P2P tunnels, but there are a few more that I forgot when I recorded the video. ・まとめ AE2のみでも、各種素材要求物の自動化や実質容量を劇的に増やすこともできる。単体導入や、MODPackに入っていた場合でも安心。 が、強いこだわりや複雑な施設による負荷を避けたいなら、アドオンの「AE2 Stuff」を同時に導入すると、面倒な自動設備を数ブロックに圧縮できるため. When used in conjunction with the Quantum Link Chamber, the block's texture and shape will connect with the surrounding blocks, forming the Quantum Network Bridge. MeefMagnet goes through how to increase the size of your ME Controller and how to reorganize it for maximum usable channels. Nope. When I play AE2 I usually start off with a tiny Ad-hoc system (no Controller, just use an Energy Acceptor; you get 8 channels) just so I can start using the Crafting Terminal and power Crystal Growth Accelerators (switched on/off with a Toggle Bus), and then jump right to this kind of clearly overkill, 8-Main, 1-P2P Controller setup prior to. In my Mod Pack, unless it's called something else i can see only the World Anchor and a ChunkLoader (MineFactory Reloaded), the Anchor does 1 chunk and the MineFactory one can be configured as 0, 1 or 2 radius, which i think having one of those wont cover ME Controllers/Drives and Quantum Ring. The ME 1k Storage cell is the smallest and easiest to craft to get started, and can easily. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several. For convenience, you need to attach a dense cable on each side of a controller except those four that are in the inside circle. • 4 yr. Configuration file (ae2ao. Basic fluix cables have a maximum of 8 channels that can connect in a single branch. I have an Empowerer from Actually Additions 2, but it seems to be fighting for bandwidth with my Molecular Assemblers. • 22 days ago. You might as well just make a converter for whatever systems. It has its own energy units which will be created inside the machine itself. anabsolutesloth • 4 yr. The CPU must contain at least 1 storage component. So putting some thoughts into it will certainly reward more compared to a quick solution. Follow the Feed The Beast Wiki on Discord or Mastodon! READ MORE. I didn’t use it much, but rushing rf tools storage scanner acts like a ae2 system that uses inventories in the world. Refined Storage vs Applied Energistics 2 for displaying a. 2 In Conclusion . Import bus pulls items from an inventory into the ME system. I have a one-controller carrier network between a hollow 3x3 controller and my devices and I'm at 140 channels without breaking a sweat. To summarize what everyone else is saying: if you want a "vanilla" AE2 solution use a quantum bridge otherwise, if you want to extend your System to the. Got 2 Mekanism ore quadrupling setups but they aren't running constantly. While using. Do what you normally would to join 2 p2ps and see whether it works. D:perTickNetworkBridge= the number of AE units required to power a Quantnum Network Bridge. AE2 cables do not have a distance restriction, they have a connected device restriction, called "channels". In IC2, the basic solid-fuel burning Generator produces 10 EU/t, and the most end-game generator (Liquid Cooled Reactor) can produce about 1,000 EU/t. . AE2 has a 'spatial storage' component. D:perTickNetworkBridge= the number of AE units required to power a Quantnum Network Bridge. extenders= the maximum number of wireless boosters ( capped at 64 ). Many Pattern Provider as you need to feed your recipes. That's 32x32 channels (1,024) going through a single dense cable line. 2. ME Cable is added by Applied Energistics. If you are using more than maybe 5 controller blocks combined you are doing it wrong (unless it's for aesthetics). ME Controller · ME Terminal ·. Not too shabby. Without a controller, an ME network can handle only up to 8 channels, with a controller it can handle more (well, 32 per side of the controller, as usual). quartz cable wont connect networks, just power. A 4k disk is 4x the size and cost of a 1k disk and the index is 4x bigger. You can tell this by watching the AE controller energy go above its max amount before resetting back to its max amount and repeating. The machine requires either a Wooden Crank (placed on top of the block) or power in the form of Redstone Flux (RF), Energy Units (EU), and Teslas (Energy can only be inserted from. In games like Factorio, getting resources is automated right away. So for example, if you have an ME Cable facing all six sides, you can have a maximum (assuming no one cross-connects) of 54 channels from a single ME Controller. Yes, an ME Interface can use 6 MAs at the same time without other augments. When your networks starts to grow, so must your ME Controller. 94. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). . the energy acceptor is now passing power to the main network, which is passing it to. Controllers can have maximum of 2 adjacent blocks in at most 1 axis (the cannot have a plus sign rule). Manyullyn 前回宣言した通り、今回からME倉庫の構築を目標として. Not connected to same dense cable. One of the most popular methods is hooking an import bus (with acceleration upgrades) to an ender chest from ender storage. Or so I heard. " Such networks are limited to only 8 Channels. Right-clicking materials on a Drawer Controller will automatically deposit the materials. Going through Pattern Provider and ME Interface in the new version. There are very few situations where putting an Export Bus and Storage Bus on the same inventory is actually useful (and infinite loops are a waste of both AE power and computer processing). No crafting recipe for the AE2 version only chisel. Each subnetwork of 6 drives, ME Interface and ME Storage bus form an ad-hoc network without a controller. 432. You can use 32 interfaces. Get the configuration of the interface. Join. Right-clicking materials on a Drawer Controller will automatically deposit the materials. The Charger is a machine added by Applied Energistics 2. AE2 makes you think about what you build rather than plopping down cables and other devices. one ME Access Terminal or ME Crafting Terminal if you have chosen an ME Drive as your first Storage. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. Screenshots. The current power level is indicated by a coloured bar on the front of the block. I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. Each device takes one channel. In the case of AE2's assemblers, that's probably going to mean a controller, a single assembler block, a memory block, and a hard drive; but again, I'm guessing. The questin i have is, if it is like this: the more surfaces the more…AE2 ME Network Freezing? This issue seems to keep coming up for me. Feed The Beast Wiki. MEコントローラ (ME Controller) スカイストーンブロック:4+純粋なフルーシュクリスタル:4+上級プロセッサ:1. I was partly going for wanting it to look a bit diff anyhow. As I continue to dabble I may add in checking on the status of the requested jobs and bound the looping to when all requested jobs per loop-pass have been completed. gradle. Your main network + P2P network both require power. We also review how ME Controllers connect. Thats: 16 * 1024 * 1024 * 10 * 32 = 5'368'709'120 items per side of an ME controller. An RS system will cause more lag than an AE2 system that's 4 times the size. You only need 1 cable at the top of the 8 drives in each “block”. With the way tags and flattening works, it also would not be of much use. Controller Network - A network with a Controller. 10 Type : Item Stackable : Yes (64) Printed Silicon is an item added by the Applied Energistics 2 mod. An ME Controller can have 2 adjacent blocks in at most 1 axis Rule #3 essentially means that, of the 3 axes (north/south, east/west, up/down), only one of those axes can have 2 controller blocks on both sides of any given controller and that the other axes may only have one controller after that. Channels are just a funny way to say bandwidth. AE2 network is small, 20 64K drives, 20 ME interfaces and 20 molecular assemblers but no patterns (issue happens with just controller). The main reason I may choose to put down more Controllers, say a 1x5 block, is to make it a bit easier to attach cables to it without making a mess. If dyed, cables will not connect to ones of a different color, which makes it easier to have many networks close together. I've tried. Yeah what you found is actually a main part of "normal" ae2 progression, the ad hoc system. Jan 15, 2015. 3 sides total of 24 channels instead of using 4 sides using 4-6 channels. Use quartz to supply power and short-circuit the ME signal (force it to go through the p2p); just go around the p2p with quartz. An ME Controller has a built in power buffer, while an Energy Acceptor has practically none. ME Controllers are thus disabled as a result, so anything relating to the. While the ME Chest is a great way to get introduced to the concept of ME, to really take advantage you need to. Minecraft Version: 1. It is the new and overhauled version of the original Applied Energistics mod. Today I gonna show you how to use the cables from Applied Energistics 2. (5) some EnderIO basic conduit filters. Almost right. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. In practice the amount of channels you actually need comes down to how much you intend to solve with AE2 and the modpack you are playing. B:Channels=true. Connect up a few dense cables to the underside and all 30 interfaces connect fine. Notifications Fork 556; Star 1. I'll tell you what are the differences between them, How to build a Hilber. One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. 17. Thi. The ME Quantum Network Bridge device is a multiblock unit capable of connecting distant ME networks together. 5% energy tax is deducted as transfer loss. Edit 2: I solved it! I don't know what it was that was causing the items to disappear but I just tore out all the ME controllers and replaced each cable connection one by one to try and find the one causing the problem, but after I did that it just went back to normal. But what is interesting is that the "other side" of the P2P interface is actually managed like a second distinct ME network multiblock. The ME Controller is a block added by the Applied Energistics 2 mod. The ME Controller is the core machine required for any Applied Energistics network. The mod includes a network-based storage sy. Deposits. 3. Void junk/non stackable items or store. ago. Quick note, sticking the Cell into a crafting grid when it has no Items stored as data will also work to extract the component. It allows items to be inserted into or extracted from the ME System it is connected to. Featured playlist. Used versions: Forge: 2810 AE2: stable 6, Rv6 MC: 1. I'm still not able to find out how I can connect a secondary terminal 50 blocks away though. 1. The Spatial IO Port is a block added by the Applied Energistics 2 mod. Top 3% Rank by size. Every machine in AE2 takes up 1 channel. The Controller will need power to work. Most are so small that they don't even have their own Controller, which is called "Ad-Hoc. Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. . Interior: 135 Tunnels giving 4320 channels, 5 sides on the outside are required to extract these tunnels. 2 One route to the controller: 1. The ME Controller allows 32 channels to be used per side. In this episode of Applied Energistics 2, we review how Smart and Dense Cables connect and interact with devices. 1. Glass, Covered and Smart cables all support 8 channels. it's probably because of nested recipes, calculations will take forever to calculate tier 1 essence -> tier 2 -> tier 3 -> tier 4 -> tier 5 -> tier 6 essences needed to craft each tier of seeds. It is the new and overhauled version of the original Applied Energistics mod. If there's "Extra Cells 2" in your pack, the biggest storage cells are 16M (instead of 64k). i would suggest using a RFTools crafter to do a passive autocraft to keep stock of each level of essence (using drawers or something) as opposed to. furnace, puverisor, maga crusible) or onther not the CPU. According to my own calculations, the maximum amount of items you can store is somewhere are 20,000,000. (4th picture) So if you make each set of the controllers max size and have all the faces connect to the center network you can have ALOT of channels. The ME Controller is a block added by the Applied Energistics 2 mod. Dense cables = 32 channel carrying capacity along the line. . The conversion is 4 RF -> 2 AE <- 1 EU. The 1k Storage Cell provides storage for 1024 bytes worth of items, and up to 63 different item types. All the autocrafting bits and bobs are still there and operational. Neverthless I do not see many arguments to convince me about this option. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. Applied Energistics 2. Channels. While hovering over an item that has a guide page, hold the W key to open the corresponding guide page. ---> which I have all 3 controller blocks connected. Two ME Controller blocks make a 1 x 2 multiblock structure which has a total of ten faces, or 80 channels with regular ME Cable. I've added a new block to AE2 Stuff 0. Join. Up to 64 Boosters may be inserted for a total range of 528 block radius and an energy cost of 4. 4kRF) and i can't seem to get any more energy into the system with energy acceptors. One Route to the controller: AE2 devices auto-connect. ControllerLimits (initially -> false) - allows you to install several controllers in the same network (in the false state, allows you to set an unlimited number of controllers);. As. you are also advised to use storage drawers with ae2. 8 channels is always maximum, after that you need a controller. Disble chanels limit; And settings for all upper; Setting for conroller max size; Setting for amount of item and fluid per byte . There are limits to the number of devices you can have in a system (I think 8 without a controller, and then it's limited to the connections to the controller), but, as far as I can tell, all the devices can be interchangable, you could have 8 ME drives as a system, you just wouldn't be able to actually DO. First Appearance : MC 1. Any data-storing or data-using device needs a channel. I tried using Energy Acceptors but that didn't work to bridge the cap. . so you can go Energy Acceptor (1 channel) -> Main network cable->quartz cable->transport cable. I have a large ME controller setup in my primary base, P2P tunnels leading to storage, autocrafting and crafting cpus. Example: I have an ME controller (6 sides). P2P stands for Point to Point. You can get more by utilizing every side you have and that would make it worth it you also don’t need dense cables coming off each thing you can place p2ps directly on the controllers unless you are doing it for aesthetics. Also, AE2 uses priorities intelligently. As the other comments say You’ve got too many cables connecting. ItIsHappy • 9 yr. They're both visually appealing in their own ways to me. No branches or pull requests. 7. Items like the Interface, Import Bus, ME Drive block, etc all consume 1 channel per device. ME Storage Cell are used to store items; for example, possessing a 64k ME Storage Cell allows the player to store up to. 1 AE2 Channel Surfing for Newbies (A Reference Guide for the Rest Of Us!) 1. Describe the bug: After restarting the server, all P2P buses indicate that they are connected. This structure can be built in any cuboid, or size as long as the following Criteria are met. g. This allows the mod (Applied Energistics 2) to accept multiple forms of power, but not be a totally broken power converter. Center blocks of each wall must be ME Heat Vents. The crafting CPU as a multi-block only requires a single channel for the entire. Dense, P2P and Quantum Ring all support 32 channels. A Network requires power, which can be provided by various blocks, and may require ME. Even mekanism has a system for it, though in this case its worse than. The bus priority should be extremely high, set it to 10000 to be positive. Configuration file (ae2ao. 12. More posts you may likeDrawer A. シングルプレイ. 隣接した水での各種クォーツの種の成長を加速させる。. MEチェスト1. 91. A "Sub-Network" is a separate ME Network that augments another network. A 2x2 multiblock of controllers would have 24 faces, so 768 channels. As. MK234. It is used to connect the components of a ME Network. You can use this to position the contoller in the middle of the P2P cable and get 32 pairs on a dense cable (see the album I posted) or make the P2P system a. 0:00 / 9:22. After the move I. Today we will. Once the system detects named item 1 has finished it’ll put it and the next 8 components and named item 1 into the chest. 生産 :40AE/t. アイテムをデジタルデータ化して貯蔵、運用するといった趣のMOD。. " Such networks are limited to only 8 Channels. . 10) and remove a couple of potentially confusing commented-out lines: OpenComputers 1. The mod allows you to: Remove channel restrictions; Connect controllers via cable; Expand or shrink maximum multiblock size from controllers. Ok, so channels are what are used to transfer data in AE2. This is mainly done to improve performance because ae2 would have to do a lot of network logic calculation for those connections the way it is coded. 0. A Sky Factory 4 Tutorial on how to setup a basic Applied Energistics ME System. the network took shows 2. 3 Controlling the Network . at least one Storage Block (ME Drive or ME Chest) The following are rather optional. Easy solution, create a quantum bridge for each of your "corridors" and attach each to a dense cable coming off your controller, that'll give you 32 channels per corridor to play with. ME Controller · ME Power Relay. Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is. However, you will need to reconnect a P2P bus (per dense cable). RS is far better if you don't want complexity and you aren't building a large system. Every machine in AE2 takes up 1 channel. Contents. This setup provides 2304 channels (if I calculated it properly), so you can hook up 2304 different devices, such as furnaces or chests, or alloy smelters, sagmills, storage drawers, ME Drives (also part of AE2 - lets you store items digitally)There are two ways. On Thu, Feb 18, 2016 at 3:13 PM TTLPcraft notifications@github. will post updates on free time to show my advancement in the base. 000,- if you set it up with only 64k units (no co unit, no crafting monitor). If the ME controller hub is working fine, then attached your p2p to one face first of the hub thats powered and the other p2p to the location. The 1k ME Storage Cell is the first tier of item storage added by Applied Energistics 2. SSD can have as many of these ad-hoc networks as you want. One actively pulls items, one passively accepts items. The rules for a valid SCS are, A minium size of 3x3x3 ( this will capture a single block. If you hook that up to any storage and connect it to your your system all the items in said storage will now be visible to the system. Applied Energisticsについて. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. Contents. 2. Make sure that none of the cables of the same colors attach to each other, use different colors for cables and do not attach fluix cables directly to the. . The developers of the pack have turned off AE2's channel system, if you'd like to re-enable it, consider the following: Find modpack's files -> Open config folder -> Find "AppliedEnergistics2. Each block will use 10 + distance 2 AE/t (configurable)I dont really understand Ae2 nearly as much as i see most people do here on this sub, but Im trying to setup a large crafting grid of a 3x3x3 block, alternating between ME Interface's and Molecular Assemblers. . There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. No. The crafting CPU as a multi-block only requires a single channel for the entire. 2. I wouldn't suggest a turbine until you can use the power of a max size one which is 80 blades, uses 2000 mb/t of steam, and produces around 27k RF/t depending on the power multiplier in the configs. Top 1% Rank by size . RF等からAEエネルギーへの変換機能を持ち、1面につき32チャンネルを扱える装置。. Configuration file (ae2ao. store method on ME controllers, allowing the storing of item information in a database for use with the export bus. It doesn't matter if you can pump in 42 Billion RF/t if the local buffer can't accept it, and you run into power problems if you manage to drain the entire buffer in 1 tick. The ME Dense Cable is the only cable that can support 32 channel simultaneously so it can be used as a main data line to connect to another ME Controller or branch off into 8 channel. Remember that AE devices link to each other and connect to the network. You can get more by utilizing every side you have and that would make it worth it you also don’t need dense cables coming off each thing you can place p2ps directly on the controllers unless you are doing it for aesthetics. If you’re having trouble executing the mod, try reading this article of ours that teaches mod implementation for Minecraft. This a max amount of 314. 10 ae2 was just to annoying and it felt as if they ruined my favourite mid but thank you for this post cause I like the concept of everything ae2 stands for like the inscribed and meteorites to make things but growing certus and channels mad me think wtf did he do. The Quantum Field Ring is a block added by Applied Energistics that is used in the creation of the ME Quantum Network Bridge. Top 1% Rank by size . BUT I fear I might be out of channels one day, once I have so many ME Storage Buses. When I expanded it I searched for a way to have 32 interfaces on one ME Dense Cable. It is highly recommended following its specification and further considering an upper bound for the dependency version. However, a regular glass cable will only hold 8. Or so I heard. Alternative, use a level controller pointing to the machine or an export bus/interface with a crafting card set to make the item you want. It is the main part of any ME Network which handles everything like a CPU does in your computer. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side. The p2p network by itself is a normal ME network (with the one difference that it connects p2p tunnels instead of storage/crafting devices etc. The power source is a vibration chamber, i assumed it didnt need a power acceptor since it have ae directly. 2. The channels documentation states controllers still reduce power consumption with infinite channels, so I added some controllers to our network. If you want some kind of storage- which in. Creating this device is extremely expensive due to it requiring a Quantum Link Chamber in the center, and eight Quantum Field Rings around it. . Here is a little breakdown of how I wired it. Nov 21, 2014. The ME System is used for. All Spatial Pylons must be either connected with cable or via a QNB, and on the same network. For items I know for sure it exists, I saw it. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side.